Antechamber — Force Field Parameterization
SkillDev toolsUse AmberTools antechamber for molecular force field parameterization. Generates GAFF/GAFF2 parameters and AM1-BCC or RESP charges for use in AMBER or LAMMPS classical MD simulations.
Available today. Use it from your connected AI after setup.
No other account needed.
Connect ahel once, and every AI you use reads what you have installed.
Then ask your AI: use the Antechamber — Force Field Parameterization skill
What this skill tells your AI
The instructions your AI receives, as published by hello-qm/catgo-lrg in .claude/skills/antechamber/SKILL.md and read by ahel’s review.
When to Use
- User needs GAFF/GAFF2 atom types and parameters for a small molecule
- User wants AM1-BCC or RESP partial atomic charges
- User is preparing a molecule for classical MD with AMBER or LAMMPS
- User needs to generate topology (prmtop) and coordinate (inpcrd) files
Prerequisites
- AmberTools installed (
antechamber --help) - Input molecule structure (mol2, pdb, or Gaussian output for RESP)
- For RESP charges: Gaussian output with
pop=mk iop(6/33=2)ESP data
Workflow Steps
1. Generate GAFF parameters with AM1-BCC charges
catgo_workflow_engine(action="add_task", params={
"workflow_id": "wf_xxx",
"task_type": "shell",
"name": "antechamber_param",
"command": "bash parameterize.sh",
"input_files": {
"parameterize.sh": "<script content>",
"molecule.pdb": "<molecule structure>"
},
"system_name": "ligand_param"
})
Parameterization Script — AM1-BCC Charges
#!/bin/bash
set -e
# Step 1: Assign GAFF2 atom types and AM1-BCC charges
antechamber -i molecule.pdb -fi pdb \
-o molecule.mol2 -fo mol2 \
-c bcc -at gaff2 \
-nc 0 -m 1 \
-rn LIG
# Step 2: Check for missing parameters
parmchk2 -i molecule.mol2 -f mol2 \
-o molecule.frcmod -a Y
# Step 3: Build topology with tleap
cat > tleap.in << 'EOF'
source leaprc.gaff2
LIG = loadmol2 molecule.mol2
loadamberparams molecule.frcmod
check LIG
saveamberparm LIG molecule.prmtop molecule.inpcrd
savemol2 LIG molecule_leap.mol2 1
quit
EOF
tleap -f tleap.in > tleap.log 2>&1
echo "Generated: molecule.prmtop molecule.inpcrd"
Parameterization Script — RESP Charges
For higher-quality charges, use RESP from Gaussian ESP:
#!/bin/bash
set -e
# Step 1: Generate Gaussian input for ESP
antechamber -i molecule.pdb -fi pdb \
-o molecule.gjf -fo gcrt \
-gm "%mem=4GB" -gn "%nproc=8" \
-ge "molecule.gesp" \
-gk "#HF/6-31G* opt pop=mk iop(6/33=2)"
# Step 2: Run Gaussian (separate task)
# g16 molecule.gjf
# Step 3: Extract RESP charges from Gaussian output
antechamber -i molecule.log -fi gout \
-o molecule.mol2 -fo mol2 \
-c resp -at gaff2 \
-nc 0 -m 1 -rn LIG
# Step 4: Check and build topology (same as AM1-BCC)
parmchk2 -i molecule.mol2 -f mol2 -o molecule.frcmod -a Y
cat > tleap.in << 'EOF'
source leaprc.gaff2
LIG = loadmol2 molecule.mol2
loadamberparams molecule.frcmod
check LIG
saveamberparm LIG molecule.prmtop molecule.inpcrd
quit
EOF
tleap -f tleap.in > tleap.log 2>&1
Solvation with tleap
After parameterization, solvate the molecule:
source leaprc.water.tip3p
LIG = loadmol2 molecule.mol2
loadamberparams molecule.frcmod
solvateBox LIG TIP3PBOX 12.0
addIonsRand LIG Na+ 0 Cl- 0 # Neutralize
saveamberparm LIG solvated.prmtop solvated.inpcrd
quit
Parameter Guidance
| Flag | Purpose |
|---|---|
-c bcc | AM1-BCC charges (fast, good for most organic molecules) |
-c resp | RESP charges (requires Gaussian ESP, higher quality) |
-at gaff2 | GAFF2 atom types (preferred over gaff) |
-nc 0 | Net charge of molecule |
-m 1 | Spin multiplicity |
-rn LIG | Residue name (3 chars max) |
-fi / -fo | Input/output format (pdb, mol2, gout, gcrt) |
Common Pitfalls
- Wrong net charge —
-ncmust match the actual molecular charge. Wrong charge gives wrong AM1-BCC charges. - Missing parameters —
parmchk2with-a Yfills gaps by analogy but warns. Checkmolecule.frcmodforATTNlines. - Atom name conflicts — tleap requires unique atom names within a residue. antechamber usually handles this.
- RESP without ESP — RESP charges require a Gaussian calculation with
pop=mk iop(6/33=2). AM1-BCC does not. - GAFF vs GAFF2 — use GAFF2 (
-at gaff2,leaprc.gaff2) for improved parameters. Do not mix GAFF and GAFF2. - Radical species — antechamber struggles with radicals and metals. Consider manual parameterization.
- Large molecules — AM1 optimization in antechamber can be slow for >100 atoms. Pre-optimize geometry.
Signals
- GitHub stars
- 196
- Forks
- 23
- Last commit
- Sep 2026
Advanced
- Catalog kind
- skill
- Gateway key
antechamber- Source
- github.com/hello-qm/catgo-lrg