AutoCAD 2026 + 天正暖通 HVAC

SkillDatabases & data

Use when controlling AutoCAD 2026 with Tianzheng HVAC T30 through the autocad_tianzheng MCP server, including connecting the THvac30V1 profile, reading or creating DWG engineering files, scanning layers/entities/blocks/text into SQLite/JSON/XLSX, running Tianzheng HVAC commands, loading Tianzheng ARX modules, or diagnosing Tangent path issues.

Use AutoCAD 2026 + 天正暖通 HVAC in Claude, ChatGPT or Ahel Desktop

Free. Sign in, add AutoCAD 2026 + 天正暖通 HVAC and connect your AI. About a minute.

Also: Claude Code · Cursor · Codex

Then ask your AI: use the AutoCAD 2026 + 天正暖通 HVAC skill

Details

Instructions available. Your AI can read the instructions. Execution depends on the setup they require.

Add Ahel to your AI once: Claude, ChatGPT, Cursor, Claude Code or Codex. Then ask it to use this.

AutoCAD 2026 + 天正暖通 HVACStart free

What this skill tells your AI

The instructions your AI receives, as published by hashgraph-online/awesome-codex-plugins in plugins/summer521521/AutoCAD_Tianzheng_plugin/skills/autocad-tianzheng-hvac/SKILL.md and read by Ahel’s review.

适用范围

用这个 skill 处理本机 AutoCAD 2026 + 天正暖通 T30V1 的连接、读图、建图、保存、导出和排障。默认 MCP server 是 autocad_tianzheng;在 Codex 设置页的 MCP servers 里,它显示在 "From plugins" 列表下,不一定出现在手动 "Servers" 列表里。

机器相关路径从环境变量读取:

  • AutoCAD: AUTOCAD_EXE,例如 <AutoCAD 2026 install>\acad.exe
  • 天正暖通根目录: TIANZHENG_ROOT,例如 <Tangent THvacT30V1 root>
  • 天正 profile: THvac30V1
  • COM 自动化 profile: CodexAutomation
  • AutoCAD 2026 COM ProgID: AutoCAD.Application.25.1
  • MCP 工程: AUTOCAD_TIANZHENG_MCP_ROOT,指向本机 multiCAD-mcp 工作树
  • Python 解释器: AUTOCAD_TIANZHENG_PYTHON,可选;未设置时使用当前环境里的 python
  • 默认输出: 优先放在 MCP 工程外的用户指定工作目录;不要写入插件仓库

标准连接流程

  1. 先连接指定 CAD 类型,不要依赖自动探测。稳定自动化模式通过 CodexAutomation 启动干净 AutoCAD 2026;如果用户已手动打开天正,则可只附加当前运行会话。
[{"action":"connect","cad_type":"tianzheng_hvac"}]

把上面的 JSON 字符串传给 manage_session。

  1. 连接后立刻探测天正状态:
[{"action":"probe"}]

把上面的 JSON 字符串传给 manage_tianzheng。重点看 current_profile、tangent_root_exists、missing_paths、support_path、trusted_paths 和三个 ARX 文件是否存在。

常见正常状态:

  • 用户手动打开天正时,current_profile 通常是 THvac30V1
  • Codex 自动化冷启动时,current_profile 通常是 CodexAutomation
  1. 做天正命令前再显式加载暖通 ARX:
[{"action":"load_arx"}]

默认加载 Tch_HvacCmd.arx、Tch_PipeBase.arx、tch_pipewire.arx。不要把 auto_load_arx 改成默认开启;历史上自动加载天正核心 ARX 可能触发 AutoCAD 崩溃。

读图与索引

读取工程图时先用普通 CAD 工具查询图层、块、实体,再用天正索引补充可检索数据。扫描 ModelSpace 到 SQLite:

[{
  "action":"scan_index",
  "db_path":"<output-root>\\index\\autocad_tianzheng_index.sqlite",
  "json_path":"<output-root>\\index\\autocad_tianzheng_index.json",
  "xlsx_path":"<output-root>\\index\\autocad_tianzheng_index.xlsx"
}]

索引内容包括图纸路径、实体 handle、对象类型、图层、颜色、线型、文字、块名/名称、坐标 JSON。需要追溯对象时优先用 handle。

建图与保存

新建图纸先调用 manage_files 的 new,再用 draw_entities 画基础实体和文字。保存用绝对路径:

save|<output-root>\drawings\smoke_autocad_tianzheng.dwg

复杂工程文件优先分层创建:轴网/墙体/风管/水管/设备/标注/文字分别放到清晰图层;块名、图层名、文字标注要可检索。不要在没有用户确认的情况下覆盖已有 DWG。

执行天正命令

通过 manage_tianzheng 的 run_command 执行低风险命令:

[{"action":"run_command","command":"_ABOUT","timeout_sec":10}]

如果返回 Command is still active or waiting for user input,说明命令大概率需要人工点选、输入或对话框确认。不要继续盲目发送回车或坐标,先报告需要人工交互。

排障顺序

  1. manage_session 连接失败:确认 AutoCAD 2026 路径存在,再看 AutoCAD.Application.25.1 是否可用。不要混用旧版 AutoCAD ProgID。
  2. probe 显示 tangent_root_exists=false 或 ARX 文件不存在:确认 TIANZHENG_ROOT 指向正确的天正暖通安装目录。
  3. CodexAutomation 下没有天正 SupportPath/TRUSTEDPATHS 是预期状态;只有用户手动打开天正 THvac30V1 时才应看到天正路径。
  4. ARX 加载失败:确认文件在 TIANZHENG_ROOT\SYS25x64 下,再用 load_arx 单独加载具体路径。
  5. Codex 看不到 MCP 工具:先确认设置页 "From plugins" 里有 autocad_tianzheng,再重启 Codex,让新环境变量和缓存插件重新加载。

Signals

GitHub stars
1k
Forks
316
Last commit
Oct 2026
Advanced
Item type
skill
Key
autocad-tianzheng-hvac
Source
github.com/hashgraph-online/awesome-codex-plugins