Mapping lab/observation names to LOINC
SkillDev toolsLets your agent convert lab test and clinical observation names into standard LOINC codes.
Available today. Use it from your connected AI after setup.
No other account needed.
Connect ahel once, and every AI you use reads what you have installed.
Then ask your AI: use the Mapping lab/observation names to LOINC skill
About this capability
Maps laboratory and clinical observation names extracted by OpenMed to LOINC codes using the public Regenstrief LOINC and FHIR terminology APIs. Use when the user wants to code lab tests, vital signs, or observations to LOINC, resolve a test name plus specimen and method to the correct LOINC part-mo
What this skill tells your AI
The instructions your AI receives, as published by maziyarpanahi/openmed in skills/mapping-loinc/SKILL.md and read by ahel’s review.
Ground free-text lab and observation names that OpenMed surfaces to LOINC (Logical Observation Identifiers Names and Codes), the universal standard for identifying what was measured. A LOINC code is a fully specified observation — not just an analyte but the full six-axis model: Component, Property, Time, System (specimen), Scale, Method.
LOINC is free to use. It is published by the Regenstrief Institute under the
LOINC license: you accept terms-of-use (and register to download the table), but
there is no fee and no per-use restriction. The standard, public path for
license-clean mapping is a FHIR terminology server exposing LOINC via
$lookup / $validate-code, or Regenstrief's hosted fhir.loinc.org.
When to use
- A note or report contains lab/observation names ("serum potassium", "hemoglobin A1c", "blood pressure") and you need a stable LOINC code each.
- You must disambiguate by specimen/system ("glucose in serum" vs "glucose in urine") or method ("HbA1c by HPLC").
- You need UCUM units to pair with the result value, or a US Core
Observation(Laboratory Result) coded with LOINC. - You are mapping a panel (e.g. CBC, BMP) vs its individual analytes.
For diagnoses/procedures use coding-icd10; for drugs use normalizing-rxnorm;
LOINC is for observations and measurements.
Quick start (real LOINC / FHIR terminology calls)
Regenstrief hosts a public FHIR terminology endpoint at https://fhir.loinc.org
(HTTP Basic auth with your free LOINC account). Many sites instead point at their
own server (HAPI, Ontoserver, Snowstorm-with-LOINC). The operations are the same.
import requests
from requests.auth import HTTPBasicAuth
FHIR = "https://fhir.loinc.org"
AUTH = HTTPBasicAuth("YOUR_LOINC_USER", "YOUR_LOINC_PASSWORD") # free account
LOINC_SYSTEM = "http://loinc.org"
def lookup(code: str) -> dict:
"""$lookup: return the fully specified name + axes for a LOINC code."""
r = requests.get(
f"{FHIR}/CodeSystem/$lookup",
params={"system": LOINC_SYSTEM, "code": code},
auth=AUTH, headers={"Accept": "application/fhir+json"}, timeout=15,
)
r.raise_for_status()
return r.json()
def validate(code: str, display: str) -> bool:
r = requests.get(
f"{FHIR}/CodeSystem/$validate-code",
params={"url": LOINC_SYSTEM, "code": code, "display": display},
auth=AUTH, headers={"Accept": "application/fhir+json"}, timeout=15,
)
r.raise_for_status()
params = {p["name"]: p.get("valueBoolean") for p in r.json().get("parameter", [])}
return bool(params.get("result"))
print(lookup("2823-3")) # Potassium [Moles/volume] in Serum or Plasma
Search candidate LOINC codes from a text name with the Regenstrief search API
(https://loinc.org/search/) or a ValueSet/$expand filter on your server:
def expand_filter(text: str, count: int = 10) -> list[dict]:
"""Text-filter the LOINC code system to candidate concepts."""
r = requests.get(
f"{FHIR}/ValueSet/$expand",
params={"url": "http://loinc.org/vs", "filter": text, "count": count},
auth=AUTH, headers={"Accept": "application/fhir+json"}, timeout=20,
)
r.raise_for_status()
return r.json().get("expansion", {}).get("contains", [])
Workflow
- Extract observation/analyte mentions with OpenMed.
- Assemble the axes you have from surrounding text: component (what), specimen/system (serum, urine, blood), method (HPLC, immunoassay), and scale (quantitative vs ordinal). More axes → a more specific, correct LOINC.
- Search candidates via
$expand?filter=(or Regenstrief search). - Disambiguate by matching specimen and property. "Glucose" alone is ambiguous; "glucose, serum, mass/volume" resolves to one code.
- Validate the chosen code with
$validate-code, then$lookupto pull the long common name and the canonical UCUM example unit. - Emit
{system: "http://loinc.org", code, display}plus the UCUM unit for the result value, into a US Core Observation.
Hand-off from OpenMed
openmed.analyze_text(..., output_format="dict") returns entities, each a dict
with text, label, confidence, start, end. Lab analytes often surface
under Chemical/Disease models; run the relevant model and feed the spans in:
import openmed
note = "Labs: serum potassium 5.1 mmol/L, hemoglobin A1c 7.8 %."
result = openmed.analyze_text(
note,
model_name="chemical_detection_pubmed", # Chemical category (analytes)
output_format="dict",
)
for ent in result["entities"]:
name = ent["text"] # e.g. "potassium"
candidates = expand_filter(name, count=5) # LOINC candidates
# carry OpenMed offsets so the code is traceable to the source span
print(name, ent["start"], ent["end"], "->",
[(c["code"], c["display"]) for c in candidates[:3]])
Pair the matched LOINC with the value and unit you parse from the same line — LOINC names the test, UCUM names the unit, the value stays in the Observation. Keep only offsets and codes in your mapping table; never persist raw report text.
Edge cases & gotchas
- Specimen ambiguity is the #1 error. Always resolve System/specimen before choosing a code. Defaulting to "Serum or Plasma" when the note says urine produces a wrong but plausible LOINC.
- Panel vs analyte. "CBC" is an order/panel LOINC; the individual results (WBC, Hgb, Plt) are separate analyte LOINCs. Map at the granularity your data is recorded at.
- Method matters for some assays (e.g. HbA1c, troponin generations). If the method is documented, pick the method-specific code; otherwise use the method-less "any method" code rather than guessing.
- UCUM, not free text, for units. Convert "mg/dL" to the UCUM string
mg/dL; reject units LOINC's example unit cannot reconcile with. - Licensing (free, with terms). LOINC is free but Regenstrief-licensed:
accept the LOINC terms-of-use and register for a (free) account to call
fhir.loinc.orgor download the table. Do not obtain LOINC by bundling UMLS or SNOMED — those carry separate restricted licenses and must stay user-supplied and out-of-process (seemapping-to-snomed,linking-umls-concepts). - Local-first. OpenMed NER runs on-device; only the de-identified analyte string should reach the terminology server. No PHI over the wire.
Standards & references
- LOINC home & license: https://loinc.org/ and https://loinc.org/license/
- LOINC FHIR terminology service: https://loinc.org/fhir/
- FHIR
$lookup/$validate-code: https://hl7.org/fhir/codesystem-operation-lookup.html - UCUM units of measure: https://ucum.org/
- US Core Laboratory Result Observation: https://hl7.org/fhir/us/core/StructureDefinition-us-core-observation-lab.html
Signals
- GitHub stars
- 5k
- Forks
- 666
- Last commit
- Sep 2026
Advanced
- Catalog kind
- skill
- Gateway key
mapping-loinc- Source
- github.com/maziyarpanahi/openmed