Library: siemens_tia_scripting (v1.4.3)

Use this skill for the Siemens-supplied Python wrapper around TIA Portal Openness. It is a reference-routed skill: do not select Python merely because a task mentions TIA Portal. If the implementation route is not already explicit, start with tia-openness-roadmap.

Evidence and qualification boundary

This package is aligned to the supplied Siemens V1.4.3 artifacts:

  • English manual 109742322_TIA_Scripting_Python_DOC_V143_en.pdf, entry ID 109742322, dated 06/2026.
  • The siemens_tia_scripting.pyi stub bundled identically in the CPython 3.12, 3.13, and 3.14 wheels.
  • Siemens package metadata, changelog, and example workflows distributed with V1.4.3.

The manual and stub are the authority for public names and signatures. The changelog is the authority for version-to-version behavior notes. Static package inspection does not prove import success, installed products, licensing, live portal behavior, or project mutation on a particular engineering station.

Supported environment

  • Python 3.12.x, 3.13.x, or 3.14.x only, using the matching Windows x64 wheel.
  • The V1.4.3 manual states TIA Portal V15.1 or newer and TIA Portal Openness V15.1 or newer.
  • Siemens manifest.json lists V18-V21, while the delivered package contains adapter assemblies from V15.1 through V21.1. Treat this as mixed Siemens compatibility metadata: verify the exact installed Portal and update before promising runtime support.
  • The Windows user must belong to the Siemens TIA Openness group. The first connection can display the Siemens Openness security prompt.

Installation

Do not install an unrelated package from PyPI. Use a wheel from the Siemens download or use the extracted-file import method.

Siemens wheel

Choose the wheel whose CPython tag matches the interpreter:

py -3.12 -m pip install .\install\siemens_tia_scripting-1.4.3-cp312-cp312-win_amd64.whl
py -3.13 -m pip install .\install\siemens_tia_scripting-1.4.3-cp313-cp313-win_amd64.whl
py -3.14 -m pip install .\install\siemens_tia_scripting-1.4.3-cp314-cp314-win_amd64.whl

Install only the wheel matching the interpreter. Siemens documents IntelliSense support through this package-install path with Pylance; other language servers are not qualified in the V1.4.3 manual.

Extracted-file import

Set TIA_SCRIPTING to the extracted directory that contains siemens_tia_scripting.pyd and its Siemens adapter DLLs. Use the environment path only as a fallback when the wheel is not installed:

import importlib
import os
import sys
from pathlib import Path

try:
    ts = importlib.import_module("siemens_tia_scripting")
except ImportError as first_error:
    scripting_dir = os.environ.get("TIA_SCRIPTING")
    if not scripting_dir:
        raise RuntimeError(
            "Install the matching Siemens wheel or set TIA_SCRIPTING."
        ) from first_error

    resolved_dir = Path(scripting_dir).expanduser().resolve()
    if not (resolved_dir / "siemens_tia_scripting.pyd").is_file():
        raise RuntimeError(
            "TIA_SCRIPTING must contain siemens_tia_scripting.pyd."
        ) from first_error

    sys.path.insert(0, str(resolved_dir))
    ts = importlib.import_module("siemens_tia_scripting")

Do not copy the shipped examples' lifecycle and error handling verbatim. They are useful API-shape examples, but some V1.4.3 examples contain stale Python 3.12-only comments and do not reliably close or detach portal instances.

Public object model

siemens_tia_scripting
|-- Enums and 10 global functions
|-- ProductBundle -> Product
`-- Portal
    |-- Project
    |   |-- Device -> Module
    |   |-- Plc
    |   |   |-- DownloadConfig
    |   |   |-- ExecutionResult
    |   |   |-- ProgramBlock / SystemBlock / UserDataType
    |   |   |-- PlcTagTable -> PlcTag / UserConstant / SystemConstant
    |   |   |-- ExternalSource / ForceTable / WatchTable
    |   |   |-- TechnologyObject / SafetyAdministration
    |   |   `-- SoftwareUnit -> NamedValueType and PLC data objects
    |   |-- Hmi
    |   |   |-- HmiTagTable / HmiTag / HmiScreen / HmiScript
    |   |   `-- HmiAlarm / HmiAlarmClass / HmiConnection / HmiCycle
    |   |       / HmiGraphicList / HmiTextList
    |   |-- ProjectLibrary -> MasterCopy / LibraryType -> LibraryTypeVersion
    |   `-- ApplicationTest / RuleSet / SystemTest
    |-- ProjectServer
    `-- GlobalLibraryInfo / GlobalLibrary
        `-- LibraryType -> LibraryTypeVersion

The V1.4.3 stub contains 10 global functions and 45 public classes. Load the domain reference files below instead of expanding this entrypoint with every method.

Cross-cutting contracts

Properties

The V1.4.3 manual and stub annotate get_property(name: str) -> str and say non-string values are converted to strings where possible. The V1.3.0 changelog instead says property values are returned as their original boolean or numeric type. Because the supplied authorities conflict, generated code must not assume one representation:

value = obj.get_property(name="CreationDate")
if isinstance(value, bool):
    normalized = value
elif isinstance(value, str):
    normalized = value.strip()
else:
    normalized = value

set_property(name: str, value: str) -> int still requires a string value. Pass booleans, numbers, and enums as their documented string representation.

Export and import

The common V1.4.3 export signature is:

obj.export(
    target_directory_path=r"C:\Engineering\export",
    export_options=ts.Enums.GeneralExportOptions.WithDefaults,
    export_format=ts.Enums.GeneralExportFormats.SimaticML,
    keep_folder_structure=True,
)

Most V1.4.3 import methods accept import_options: Optional[Enums.GeneralImportOptions]. PLC/HMI bulk imports use an import root directory; explicitly named project-text, CFC, CAx, global-screen, screen-overview, configuration, and password-policy operations use file paths. Check the domain reference before choosing a path shape.

Compile and execution results

  • Device.compile(), Module.compile(), PLC compile methods, block/UDT/ technology-object compile methods, and SoftwareUnit.compile() return ExecutionResult.
  • ExecutionResult exposes get_result_state(), get_all_messages(), get_warnings(), get_errors(), get_information(), and print_result().
  • Hmi.compile_hardware() and Hmi.compile_software() remain the exception: they return True when errors exist and False when no errors exist.
  • The V1.3.0 changelog calls its breaking result change an "ExecutionReport" object, but the delivered V1.4.3 manual and stub expose the callable class as ExecutionResult. Use ExecutionResult in code.

Do not discard result objects or rely only on console logging:

result = plc.compile_software()
errors = result.get_errors()
if errors:
    raise RuntimeError("PLC compile failed: " + " | ".join(errors))

Exact V1.4.3 enums

PortalMode: WithGraphicalUserInterface=0, WithoutGraphicalUserInterface=1,
            AnyUserInterface=2
UmacUserMode: Project=0, Global=1
GeneralExportFormats: SimaticML=0, ExternalSource=1, SimaticSD=2
GeneralExportOptions: WithDefaults=0, Nan=1, WithReadOnly=2
LibraryCleanUpMode: PreserveDefaultVersionOfUnusedTypes=0, DeleteUnusedTypes=1
LibraryExportOptions: Nan=0, WithLibraryVersionInfoFile=1,
                      OnlyLibraryVersionInfoFile=2
LibraryHarmonizeOptions: HarmonizePathsAndNames=0, HarmonizePaths=1,
                         HarmonizeNames=2
LibraryDependenciesMode: DoNotAutomaticallyCreateOrReleaseDependencies=0,
                         AutomaticallyCreateOrReleaseDependenciesIfRequired=1
GeneralDownloadOptions: Hardware=0, Software=1, HardwareAndSoftware=2,
                        SoftwareOnlyChanges=3,
                        HardwareAndSoftwareOnlyChanges=4
TestSuiteTestCaseImportOptions: Nan=0, IgnoreInvalidObject=1
TestSuiteRuleSetImportOptions: Nan=0, IgnorePropertyErrors=1,
                               IgnoreMissingAttributes=2, SkipInvalidObjects=3,
                               IgnoreErrorsAndAttributes=4
GeneralImportOptions: Nan=0, Override=1, SkipInactiveCultures=2,
                      ActivateInactiveCultures=3
ConsoleLogLevel: All=0, Info=1, Warning=2, Error=3

Logging

Configure file/console logging before opening or attaching TIA Portal, and set the console level separately when required:

ts.set_logging(path=r"C:\Engineering\logs\tia-scripting.log", console=True)
ts.set_log_level(log_level=ts.Enums.ConsoleLogLevel.Info)

Reference routing

Load every reference needed by a cross-domain workflow before generating code.

ReferenceLoad for
skills/tia-python/references/global_portal.mdGlobal functions, portal lifecycle, credentials, products, devices, and modules
skills/tia-python/references/plc.mdPLC online/download, compilation, imports/exports, CFC, Safety, software units, and PLC data objects
skills/tia-python/references/hmi.mdGeneric wrapper HMI discovery, compile, import/export, and HMI object classes
skills/tia-python/references/library.mdGlobal/project libraries, master copies, types, and versions
skills/tia-python/references/project.mdProject lifecycle, transactions, project texts, CAx, project servers, and Test Suite

Destructive-operation safety and authority rules

These rules are mandatory for generated TIA Scripting Python:

  1. Treat project/library creation, import, property writes, master-copy instantiation, protection changes, delete() and other deletion calls, save, archive, compile-triggered generation, and hardware upgrade as mutations. Require explicit mutation authorization and exact selectors.
  2. Require explicit live-operation authorization before go_online(), go_offline(), download(), online comparison, online fingerprints, or any operation that communicates with a PLC. Confirm the exact target using pc_interface_type, pc_interface_name, and target_interface; never infer a target from the first device or first accessible interface.
  3. Inspect every ExecutionResult and stop on errors. For HMI compile calls, remember that True means errors exist.
  4. After generated block, tag, hardware, or HMI changes, run or request a compile_check through MCP. Do not present the project change as deployable until that check passes.
  5. Do not save, archive, commit a server session, close a portal, delete, or overwrite existing content unless that exact action was authorized.
  6. Use project.start_transaction() / project.end_transaction() only around already authorized mutations supported by the transaction, and roll back on every exception path:
transaction_open = False
try:
    project.start_transaction(
        undo_text="Authorized TIA change",
        dialog_text="Applying reviewed Python changes",
    )
    transaction_open = True
    # Perform only the already authorized mutation here.
    project.end_transaction(rollback=False)
    transaction_open = False
except Exception:
    if transaction_open:
        project.end_transaction(rollback=True)
    raise
  1. A transaction does not make an unsupported operation safe. If the wrapper or target object cannot provide the required exclusive-access, rollback, exact selection, or result evidence, route the task to C# Openness or MCP through a guarded workflow.
  2. Do not hardcode, print, or commit UMAC, Safety, know-how, module-access, or PLC master-secret credentials. Read them from the user's approved secret mechanism and pass them only to the exact authorized call.
  3. When this script attached to a user-owned portal, use portal.detach() in cleanup. Call portal.close_portal() only for an instance the script owns and only after the project disposition has been explicitly decided.

General coding guidance

  • Prefer keyword arguments; V1.4.0 added positional and keyword handling, but keyword calls preserve intent across similar string parameters.
  • Check optional returns before dereferencing them. V1.4.3 specifically fixes a null-reference defect involving optional parameters, but callers still need to handle absent TIA objects and values.
  • Preserve Unicode paths, names, and text. V1.4.0 added non-ASCII handling.
  • Scope retrieval with folder_path when the exact group is known.
  • Never use collection position such as plcs[0] as an engineering selector.
  • Keep PLC, HMI, project, library, and live-operation functions separate so each authority boundary can be reviewed independently.

Signals

GitHub stars
59
Forks
10
Last commit
Aug 2026
Advanced
Catalog kind
skill
Gateway key
tia-python
Source
github.com/czarnak/totally-integrated-claude