tia-simatic-drives

SkillCommunication

Routed by tia-openness-roadmap. Handles drive-specific engineering: Startdrive, SINAMICS, SIMATIC Drive Controller, PROFIdrive integrated properties, drive telegrams, and integrated drive configuration. Always uses C# TIA Portal Openness.

Available today. Use it from your connected AI after setup.

Connect ahel once, and every AI you use reads what you have installed.

Then ask your AI: use the tia-simatic-drives skill

What this skill tells your AI

The instructions your AI receives, as published by czarnak/totally-integrated-claude in skills/tia-simatic-drives/SKILL.md and read by ahel’s review.

Scope

Startdrive and drive-specific engineering — full C# Openness implementation.

When the roadmap routes here, the entire solution is C#. Do not mix with Python wrapper calls. Always load tia-csharp-common first (done by roadmap).


Reference files

Reference fileLoad when the task involves
references/drives-overview.mdCore patterns for Startdrive/SINAMICS engineering (Navigate, Parameters, Telegrams, DFI, Safety, Security)
references/motion-control.mdDetailed reference for Siemens.Engineering.MC namespaces (Drives, DFI, SecurityObjects, Enums)
references/download.mdStartdrive-specific and common Download/Upload check configurations
references/api-catalogue.mdComplete inventory of all 64 public types in the installed V21 Startdrive module

Execution pattern

  1. Confirm the task is drive-specific (Startdrive, SINAMICS, drive controller, PROFIdrive)
  2. Read references/drives-overview.md
  3. Resolve the drive device and drive object using exact selectors; recursively traverse nested device items and fail on zero or ambiguous matches
  4. Get DriveObjectContainer via GetService<>() on the device item to access DriveObjects
  5. Use DriveObject.Parameters for parameter access, .Telegrams for telegram find/insert/erase/size operations
  6. Use GetService<DriveFunctionInterface>() for commissioning, motor/encoder config, DFI, and drive-object activation/type handling
  7. For download/upload handling, include Startdrive-specific check configurations from Siemens.Engineering.Download.Configurations and Siemens.Engineering.Upload.Configurations
  8. For network/PROFIdrive timing — see tia-networks/references/subnets-and-nodes.md

Safety boundary

  • Require explicit live-operation authorization for online parameter writes, download/upload, factory reset, RAM-to-ROM copy, drive encryption/UMAC changes, and Safety commissioning.
  • Require explicit mutation authorization for offline parameters, telegrams, drive-object type/activation, motor/encoder projection, Technology Extension install/uninstall, and report overwrite.
  • Bind exact selectors to the project, device, nested DeviceItem, drive-object number, parameter name/number/index, telegram type, and requested value. Never use .First(), [0], or catalog-order assumptions.
  • Inventory current parameters, telegrams, topology, safety/security state, Technology Extensions, and dependent PLC/HMI configuration before mutation. Factory reset, encryption deactivation, forced package removal, and telegram deletion are destructive.
  • Inspect every boolean result and every download/upload configuration. Unknown or unsupported configurations fail closed; never approve all checks automatically.
  • Secrets must arrive as SecureString from the caller's approved secret source. Never embed, print, persist, or reconstruct passwords in examples.
  • Do not save: call project.Save() only when persistence was explicitly requested and post-change verification succeeded.
  • Static API checks are not commissioning evidence. Online state, firmware/device support, Safety acceptance, and successful drive behavior require an authorized live V21 test.

Signals

GitHub stars
59
Forks
10
Last commit
Aug 2026
Advanced
Catalog kind
skill
Gateway key
tia-simatic-drives
Source
github.com/czarnak/totally-integrated-claude