Wiring Contract
SkillDev toolsDerive this project's own integration conventions from what the code already does, draft them as a wiring contract, and hold new work to it. Closes the built-but-not-wired gap at L3 (walking skeleton) — a mechanism that ships and is never called reads green in every other check.
Available today. Use it from your connected AI after setup.
No other account needed.
Connect ahel once, and every AI you use reads what you have installed.
Then ask your AI: use the Wiring Contract skill
What this skill tells your AI
The instructions your AI receives, as published by haabe/mycelium in plugins/mycelium/skills/wiring-contract/SKILL.md and read by ahel’s review.
Answer one question for this project and then keep answering it automatically: when something is built here, what does it have to be connected to before it counts as done?
The failure is not carelessness, it is structural. A model's context makes it unable to see whether the element it just generated is referenced anywhere else, so plausible-but-unreferenced code is the expected output. Across 304,362 verified AI-authored commits in 6,275 repositories, "unused variables or parameters" is the second most frequent issue class, and "undefined variable or reference" — writer and reader disagreeing about a name or path — is the most common runtime bug category. It does not wash out: AI-authored code survives longer than human-written code (53.9% vs 69.3% line death rate), so an orphan is less likely to be cleaned up than a human's.
Every ordinary signal misses it. Tests pass, coverage rises, lint is clean, review approves — because each of those verifies a thing against itself, and wiring is a property of a pair.
When to Use
- At L3, before implementation — the walking-skeleton obligation (G-V13). A design is not complete until its joins are named.
- On an existing project, once, to discover what conventions it already has.
- After a structural change (new directory, new layer, a move) — regenerate, never hand-edit.
- When
check_wiring_contract.pyreports UNGOVERNED files you did not expect.
Workflow
1. Detect — read the repo's own majority convention
python3 "${CLAUDE_PLUGIN_ROOT}/scripts/check_wiring_contract.py" --root . --detect
This proposes a rule only where the repo already behaves that way, and records the evidence:
- id: wc-002
pattern: "scripts/*.py"
obliges:
- referenced_by: ["**/*"]
detected_from: "18 of 20 files already satisfy this"
confidence: 0.90
A rule without observed support is a preference, not a contract. Two obligation types exist and that is deliberate — referenced_by (something outside the file references it, by import, invocation, path, or a glob that matches it) and sibling_reference (a same-directory barrel or registry lists it). Nine specific obligations rot; two general ones that always run do not.
2. Review with the human — this is a draft, not a finding
Present the proposal and ask, per rule, in plain language: "18 of 20 scripts here have a caller. Should that be required?" Watch for two failure shapes:
- A majority that is an accident. Four files in a directory that happen to be referenced does not make referencing them a rule. Ask what the directory is for.
- A convention the detector cannot see. Files invoked by reflection, by a registry built at runtime, or by a config string are wired and will look orphaned. These need an exemption with a reason — and "it is hard to check" is not one.
Write the confirmed contract to .claude/harness/wiring-contract.yml. Per the evidence-writes rule, the contract is a human-confirmed draft, never written unattended.
3. Enforce — and put it where the agent will feel it
python3 "${CLAUDE_PLUGIN_ROOT}/scripts/check_wiring_contract.py" --root .
Per G-V14, add this to the command run after every change, not only to CI. Agents respond to automated signals far more reliably than to documentation: a failing command gets fixed, a guardrail paragraph in the context window may not be read at all.
4. Read the UNGOVERNED count — it is the load-bearing number
Files matching no rule are listed with a count. Zero violations across a governed subset is not zero violations. A clean report beside 300 ungoverned files describes the health of a fraction while implying the whole — the precise false green this skill exists to end. Either extend coverage or state why those files are outside it.
Output
- Creates/updates:
.claude/harness/wiring-contract.yml(human-confirmed) - Reports: violations, and the ungoverned count
- Feeds:
/mycelium:definition-of-done(G-V14 verification block),/mycelium:bvssh-check(CALMS Automationwiring_integrity)
Theory Citations
- Cockburn — walking skeleton: "a tiny implementation of the system that performs a small end-to-end function… it should link together the main architectural components." Wiring exists before features.
- Hunt & Thomas — tracer bullets: the same instinct, framed as end-to-end feedback first.
- Ford, Parsons, Kua — architecture fitness functions: objective, continuously-executed measures of properties the design must preserve. This check is one, and belongs in the pipeline rather than in a review checklist.
Deliberately NOT a catalogue
Mycelium does not ship a list of integration points to check. A sibling project hand-listed 4 component and 9 plugin integration points; such a list is stale the moment someone adds the tenth, and hand-enumerated scope is the origin of this entire failure family. The rules here are derived from the project in front of you, and regenerated when it changes.
Signals
- GitHub stars
- 45
- Forks
- 3
- Last commit
- Sep 2026
Advanced
- Catalog kind
- skill
- Gateway key
wiring-contract- Source
- github.com/haabe/mycelium